CYANA Command: atoms calibrate: Difference between revisions

From CYANA Wiki
Jump to navigation Jump to search
m (1 revision)
 
Line 10: Line 10:
== Description ==
== Description ==


Command to set the calibration constant of the atoms matched by
Command to set the calibration constant of the atoms matched by the given ''selection'' for the chosen ''peaklists''. By default, the selection made in the most recent 'atoms select' command is used, or all atoms if no selection has been made so far. The calibration constant can either be set explicitly to a given positive ''constant'', or it can be determined such as to achieve a median upper distance limit of approximately ''dref'' Å for the peaks assigned to selected atoms in the ''peaklists''. Only assignments to which a fraction of the total peak volume greater than the cutoff ''volcut'' is attributed are included when computing the median. This command sets the calibration constant of atoms, which may later be used to obtain upper distance limit restraints from assigned NOESY peaks by the command [[CYANA Commands: peaks calibrate|''peaks calibrate'']].
the selection ''string'' for the chosen ''peaklists''. By default, the
See also: [[CYANA Commands: peaks calibrate|''peaks calibrate'']], [[CYANA Commands: calibrate|''calibrate'']], [[CYANA Macro: caliba|'''caliba''']]
selection made in the most recent '''atoms select''' command is used,
or all atoms if no selection has been made so far. The calibration
constant can either be set explicitly to a given positive ''constant'',
or it can be determined such as to achieve a median upper distance
limit of approximately ''dref'' Angstrom for the peaks assigned to
selected atoms in the ''peaklists''. Only assignments to which a
fraction of the total peak volume greater than the cutoff ''volcut''
is attributed are included when computing the median. This command
sets the calibration constant of atoms, which may later be used to
obtain upper distance limit restraints from assigned NOESY peaks by
the command '''peaks calibrate'''.


== See also ==
== See also ==

Revision as of 12:50, 6 August 2009

Parameters

selection=string
(default: none)
peaklists=integer range
(default: 1..1)
constant=real
(default: -1.0)
dref=real
(default: 3.4)
volcut=real
(default: 0.66)

Description

Command to set the calibration constant of the atoms matched by the given selection for the chosen peaklists. By default, the selection made in the most recent 'atoms select' command is used, or all atoms if no selection has been made so far. The calibration constant can either be set explicitly to a given positive constant, or it can be determined such as to achieve a median upper distance limit of approximately dref Å for the peaks assigned to selected atoms in the peaklists. Only assignments to which a fraction of the total peak volume greater than the cutoff volcut is attributed are included when computing the median. This command sets the calibration constant of atoms, which may later be used to obtain upper distance limit restraints from assigned NOESY peaks by the command peaks calibrate. See also: peaks calibrate, calibrate, caliba

See also