[[CYANA Commands|back to complete commands list]]
== Parameters ==
== Parameters ==


Line 5: Line 7:
== Description ==
== Description ==


Reads a file containing atom specific lists of auto relaxation values and I(0) values.
Reads a file containing atom specific lists of auto relaxation values (rho) and back-predicted diagonal intensities, I(0) values, see * [[auto-relaxation and I(0) values]]
 
The format of the list uses the flag  -1.0000 for keeping the fitted value.
I.e. to specify the auto-relaxation value only but not the I(0) value:
 
15    SER  HA      3.7067              -1.0000
 
To use generic limits for normalization the I(0) value as:
 
15    SER  HA        -1.0000              752840293.0085

Latest revision as of 10:46, 2 April 2019

back to complete commands list

Parameters

file=filename.rho (required)

Description