CYANA Command: enoe plotbup: Difference between revisions

From CYANA Wiki
Jump to navigation Jump to search
(Created page with "back to complete commands list == Parameters == ; plot =''string'': (default: ''bupplots'') ; b0field =''real'': (required) ; tauc =''integer'': (required)...")
 
No edit summary
Line 3: Line 3:
== Parameters ==
== Parameters ==
; plot =''string'': (default: ''bupplots'')
; plot =''string'': (default: ''bupplots'')
; b0field =''real'': (required)
; tauc =''integer'': (required)
; opt =''coma separated list of integers'': (default: ''1'')
; opt =''coma separated list of integers'': (default: ''1'')



Revision as of 15:53, 11 September 2019

back to complete commands list

Parameters

plot =string
(default: bupplots)
opt =coma separated list of integers
(default: 1)

Description

This command plots the buildup data according to specified parameters.

The parameter plot is used to change the default name of the plot. The parameters b0field [MHz] and tauc [s] are necessary to plot the theoretical curve using the fitted parameters in relation to the experimental data. The parameter opt is used to choose the plotted content and specified as vector to ask for any combination (as coma separated list, i.e. opt=1,5).

opt=5 plots the chi values indicating the goodness of fit
The following options plot data either corrected or uncorrected for spin diffusion:
opt=1 experimental buildups uncorrected for spin diffusion
opt=2 experimental buildups corrected for spin diffusion
opt=3 simulated buildups with spin diffusion (TSS or FRM) 
opt=4 simulated buildups (two-spin solution)

The following options scale the data (normed to average buildup), in order to plot overlays of simulated and experimental data:
opt=6 uncorrected experimental buildups
opt=7 corrected experimental buildups
opt=8 simulated buildups with spin diffusion  (TSS or FRM)
opt=9 simulated buildups without spin diffusion (two-spin solution)