CYANA Command: enoe restraint: Difference between revisions

From CYANA Wiki
Jump to navigation Jump to search
No edit summary
 
(9 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[CYANA Commands|back to complete commands list]]


== Parameters ==
== Parameters ==


; b0field =''real'': (required)
; tauc =''real'': (required)
; errStereoFlag =''integer'': (default: ''1'')
; errStereoFlag =''integer'': (default: ''1'')
; errStereo =''real'': (default: ''-1'')
; errStereo =''real'': (default: ''-1'')
Line 12: Line 11:
; chiN =''real'': (default: ''-1'')
; chiN =''real'': (default: ''-1'')
; chiNc =''real'': (default: ''-1'')
; chiNc =''real'': (default: ''-1'')
== Description ==
== Description ==


This command converts the experimental distances to restraints for structure calculation.  
This command converts the experimental distances to restraints for structure calculation by applying tolerances where required. Furthermore, the automatic, internal expansion of distance restraints that involve pseudoatoms into ambiguous distance restraints with the corresponding hydrogen atoms is performed, in line with '''expand=1''', see * [[CYANA Variable: expand|expand]].
 
This variable controls the automatic, internal expansion of distance restraints that involve pseudoatoms into ambiguous distance restraints with the corresponding hydrogen atoms.


The parameter '''b0field''' is the field strength [MHz].  
The parameter '''errStereoFlag''' is set to change the default treatment of non-stereo specifically assigned restraints. errStereoFlag=1 is the default, errStereoFlag=0 turns this feature off.
The parameter '''tauc''' is the overall correlation time [ns].
The parameter '''errStereo''' is set to override the automatically calculated values based on the difference in spin diffusion (errStereo=-1 , default) for non-stereo specifically assigned restraints, it may be set a user specific percentage.
The parameter '''errStereoFlag'''
The parameter '''errUni''' is set to change the default tolerance for uni-directional eNOEs, default is errUni=20.
The parameter '''errStereo'''
The parameter '''errMeth''' is set to change the default tolerance for methyl eNOEs, default is errMeth=8.5.
The parameter '''errUni'''
The parameter '''errMethyleneQ''' is set to change the default tolerance for methylene pseudo eNOEs, default is errMethyleneQ=5.
The parameter '''errMeth'''
The parameter '''errAro''' is set to change the default tolerance for aromatic eNOEs normalized to a non-aromatic spin, default is errAro=11.
The parameter '''errMethyleneQ'''
The parameter '''chiN''' is set to select a fresh hold for goodness of fit for output of restraints (experimental fit not corrected for spin diffusion).
The parameter '''errAro'''
The parameter '''chiNc''' is set to select a fresh hold for goodness of fit for output of restraints (experimental fit corrected for spin diffusion).
The parameter '''chiN'''
The parameter '''chiNc'''

Latest revision as of 15:57, 11 September 2019

back to complete commands list

Parameters

errStereoFlag =integer
(default: 1)
errStereo =real
(default: -1)
errUni =real
(default: 20)
errMeth =real
(default: 8.5)
errMethyleneQ =real
(default: 5)
errAro =real
(default: 11)
chiN =real
(default: -1)
chiNc =real
(default: -1)

Description

This command converts the experimental distances to restraints for structure calculation by applying tolerances where required. Furthermore, the automatic, internal expansion of distance restraints that involve pseudoatoms into ambiguous distance restraints with the corresponding hydrogen atoms is performed, in line with expand=1, see * expand.

This variable controls the automatic, internal expansion of distance restraints that involve pseudoatoms into ambiguous distance restraints with the corresponding hydrogen atoms.

The parameter errStereoFlag is set to change the default treatment of non-stereo specifically assigned restraints. errStereoFlag=1 is the default, errStereoFlag=0 turns this feature off. The parameter errStereo is set to override the automatically calculated values based on the difference in spin diffusion (errStereo=-1 , default) for non-stereo specifically assigned restraints, it may be set a user specific percentage. The parameter errUni is set to change the default tolerance for uni-directional eNOEs, default is errUni=20. The parameter errMeth is set to change the default tolerance for methyl eNOEs, default is errMeth=8.5. The parameter errMethyleneQ is set to change the default tolerance for methylene pseudo eNOEs, default is errMethyleneQ=5. The parameter errAro is set to change the default tolerance for aromatic eNOEs normalized to a non-aromatic spin, default is errAro=11. The parameter chiN is set to select a fresh hold for goodness of fit for output of restraints (experimental fit not corrected for spin diffusion). The parameter chiNc is set to select a fresh hold for goodness of fit for output of restraints (experimental fit corrected for spin diffusion).