CYANA Command: enoe diag: Difference between revisions
 (Created page with "back to complete commands list  == Parameters ==  ; opt=''integer'': (default: ''1'')  == Description ==  This command fits the diagonal decays to obtain th...")  | 
				|||
| (7 intermediate revisions by the same user not shown) | |||
| Line 4: | Line 4: | ||
; opt=''integer'': (default: ''1'')  | ; opt=''integer'': (default: ''1'')  | ||
; plot =''string'': (default: ''izPlot'')  | |||
== Description ==  | == Description ==  | ||
| Line 9: | Line 10: | ||
This command fits the diagonal decays to obtain the auto-relaxation (rho) values  and back-predicted diagonal intensities, I(0) values.    | This command fits the diagonal decays to obtain the auto-relaxation (rho) values  and back-predicted diagonal intensities, I(0) values.    | ||
The parameter '''opt''' specifies if the spin type specific median and standard deviation of auto-relaxation (opt=2) values and back-predicted diagonal intensities, I(0) values (opt=3) are calculated. With the back-predicted diagonal intensities there is a pdf file generated containing plots of the fitted intensities divided according to classes with the mean (green line) and std deviation (red line). With the default setting (opt=1), no auto-relaxation values and  back-predicted diagonal intensities, I(0) values are calculated, instead the user may read a file or set the value(s) using the atom set command.  | |||
In the case of single mixing time measurements, the auo-relaxation value are omitted and the back-predicted diagonal intensities, I(0) values are replaced by the diagonal intensities values measured at the specific mixing time.  | |||
Latest revision as of 16:10, 20 November 2019
back to complete commands list
Parameters
- opt=integer
 - (default: 1)
 - plot =string
 - (default: izPlot)
 
Description
This command fits the diagonal decays to obtain the auto-relaxation (rho) values and back-predicted diagonal intensities, I(0) values.
The parameter opt specifies if the spin type specific median and standard deviation of auto-relaxation (opt=2) values and back-predicted diagonal intensities, I(0) values (opt=3) are calculated. With the back-predicted diagonal intensities there is a pdf file generated containing plots of the fitted intensities divided according to classes with the mean (green line) and std deviation (red line). With the default setting (opt=1), no auto-relaxation values and back-predicted diagonal intensities, I(0) values are calculated, instead the user may read a file or set the value(s) using the atom set command.
In the case of single mixing time measurements, the auo-relaxation value are omitted and the back-predicted diagonal intensities, I(0) values are replaced by the diagonal intensities values measured at the specific mixing time.