CYANA Command: enoe init: Difference between revisions

From CYANA Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 15: Line 15:


In practice, many diagonal peak decays cannot be fitted (due to spectral overlap, artifacts, etc.). Therefore, either a general average auto-relaxation rate or a spin-type specific value may be calculated in order to increase the number of calculated eNOEs.
In practice, many diagonal peak decays cannot be fitted (due to spectral overlap, artifacts, etc.). Therefore, either a general average auto-relaxation rate or a spin-type specific value may be calculated in order to increase the number of calculated eNOEs.
The parameter '''rhoavg''' allows the input of an average auto-relaxation values to be used non specifically [s-1]. However, it is also possible to read in a file containing spin type specific auto-relaxation values, see [[Selection read rho|Selection read rho]].
The parameter '''rhoavg''' allows the input of an average auto-relaxation values to be used non specifically [s-1]. However, it is also possible to read in a file containing spin type specific auto-relaxation values, see [[Selection rules|Selection rules]].


The parameter '''time''' specifies the measured NOE mixing times in ascending order [s]. The NOE mixing times are given as a coma separated list, i.e. time="0.02,0.04,0.06"
The parameter '''time''' specifies the measured NOE mixing times in ascending order [s]. The NOE mixing times are given as a coma separated list, i.e. time="0.02,0.04,0.06"

Revision as of 13:10, 17 January 2019

Parameters

normalize=integer
(default: none)
normed =integer
(default: none)
rhoavg =real
(default: none)
time =string
(default: none)

Description

Following the reading of peak lists, this command initializes the eNORA routine, fits the diagonal decays to obtain the auto-relaxation values and I(0), normalizes the cross peak intensities and fits the experimental buildups.

The diagonal peak to use for normalization is specified by the parameter normalize, using the integers 1 or 2 with the integers referring to the proton dimension in the peak list. The parameter normed specifies, if one wants to keep non-normalizable peaks (0) or only peaks that are properly normalized (1).

In practice, many diagonal peak decays cannot be fitted (due to spectral overlap, artifacts, etc.). Therefore, either a general average auto-relaxation rate or a spin-type specific value may be calculated in order to increase the number of calculated eNOEs. The parameter rhoavg allows the input of an average auto-relaxation values to be used non specifically [s-1]. However, it is also possible to read in a file containing spin type specific auto-relaxation values, see Selection rules.

The parameter time specifies the measured NOE mixing times in ascending order [s]. The NOE mixing times are given as a coma separated list, i.e. time="0.02,0.04,0.06"