CYANA Command: enoe buildup: Difference between revisions

From CYANA Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 12: Line 12:
The parameter '''plot''' is used to change the default name of the plot.
The parameter '''plot''' is used to change the default name of the plot.
The parameters '''b0field''' [MHz] and '''tauc''' [s] are necessary to plot the theoretical curve using the fitted parameters to the experimental data.
The parameters '''b0field''' [MHz] and '''tauc''' [s] are necessary to plot the theoretical curve using the fitted parameters to the experimental data.
The parameter '''opt''' is used to choose the plotted content and specified as vector to ask for any combination (as coma separated list, i.e. "opt=1,5"):
The parameter '''opt''' is used to choose the plotted content and specified as vector to ask for any combination (as coma separated list, i.e. "opt=1,5").


  opt=1 plots uncorrected exp. buildups
  opt=5 plots the chi values indicating the goodness of fit
  opt=2 plots corrected exp. buildups
 
The following plot experimental data either corrected or uncorrected for spin diffusion:
opt=1 exp. buildups uncorrected for spin diffusion
  opt=2 exp. buildups corrected for spin diffusion
  opt=3 plots simulated buildups with spin diffusion  
  opt=3 plots simulated buildups with spin diffusion  
  opt=4 plots simulated buildups (two spin)  
  opt=4 plots simulated buildups (two spin)
  opt=5 plots the chi values
   
 
The following options scale the data, in order to plot overlays of simulated and experimental data:
  opt=6 plots uncorrected experimental buildups (normed to average buildup)
  opt=6 plots uncorrected experimental buildups (normed to average buildup)
  opt=7 plots corrected experimental buildups (normed to average buildup)
  opt=7 plots corrected experimental buildups (normed to average buildup)

Revision as of 15:10, 17 January 2019

Parameters

plot =string
(default: bupplots)
b0field =real
(default: none)
tauc =integer
(default: none)
opt =coma separated list of integers
(default: 1)

Description

This command plots the buildup data according to specified parameters.

The parameter plot is used to change the default name of the plot. The parameters b0field [MHz] and tauc [s] are necessary to plot the theoretical curve using the fitted parameters to the experimental data. The parameter opt is used to choose the plotted content and specified as vector to ask for any combination (as coma separated list, i.e. "opt=1,5").

opt=5 plots the chi values indicating the goodness of fit
The following plot experimental data either corrected or uncorrected for spin diffusion:
opt=1 exp. buildups uncorrected for spin diffusion
opt=2  exp. buildups corrected for spin diffusion
opt=3 plots simulated buildups with spin diffusion 
opt=4 plots simulated buildups (two spin)

The following options scale the data, in order to plot overlays of simulated and experimental data:
opt=6 plots uncorrected experimental buildups (normed to average buildup)
opt=7 plots corrected experimental buildups (normed to average buildup)
opt=8 plots simulated buildups with spin diffusion (normed to average buildup)
opt=9 plots simulated buildups without spin diffusion (two spin) (normed to average buildup)


A spin-type specific value may be calculated to be read in a file containing spin type specific auto-relaxation values, the same file may be used to read spin-type specific I(0) values, see * read rho.