Parameters

normalize=integer
(default: none)
normed =integer
(default: none)
rhoavg =real
(default: none)
time =string
(default: none)

Description

Following the reading of peak lists, this command initializes the eNORA routine, fits the diagonal decays to obtain the auto-relaxation values and I(0), normalizes the cross peak intensities and fits the experimental buildups.

The diagonal peak to use for normalization is specified by the parameter normalize, using the integers 1 or 2 with the integers referring to the proton dimension in the peak list. The parameter normed specifies, if one wants to keep non-normalizable peaks (0) or only peaks that are properly normalized (1). The parameter rhoavg