CYANA Command: enoe buildup
Jump to navigation
Jump to search
Parameters
- plot =string
- (default: bupplots)
- b0field =real
- (default: none)
- tauc =integer
- (default: none)
- opt =coma separated list of integers
- (default: 1)
Description
This command plots the buildup data according to specified parameters.
The parameter plot is used to change the default name of the plot. The parameters b0field [MHz] and tauc [s] are necessary to plot the theoretical curve using the fitted parameters to the experimental data. The parameter opt is used to choose the plotted content and specified as vector to ask for any combination (as coma separated list, i.e. "opt=1,5").
opt=5 plots the chi values indicating the goodness of fit
The following plot experimental data either corrected or uncorrected for spin diffusion: opt=1 exp. buildups uncorrected for spin diffusion opt=2 exp. buildups corrected for spin diffusion opt=3 plots simulated buildups with spin diffusion opt=4 plots simulated buildups (two spin) The following options scale the data, in order to plot overlays of simulated and experimental data: opt=6 plots uncorrected experimental buildups (normed to average buildup) opt=7 plots corrected experimental buildups (normed to average buildup) opt=8 plots simulated buildups with spin diffusion (normed to average buildup) opt=9 plots simulated buildups without spin diffusion (two spin) (normed to average buildup)
A spin-type specific value may be calculated to be read in a file containing spin type specific auto-relaxation values, the same file may be used to read spin-type specific I(0) values,
see * read rho.