CYANA Command: enoe diag

From CYANA Wiki
Revision as of 16:18, 11 September 2019 by Dean (talk | contribs)
Jump to navigation Jump to search

back to complete commands list

Parameters

opt=integer
(default: 1)
plot =string
(default: izPlot)

Description

This command fits the diagonal decays to obtain the auto-relaxation (rho) values and back-predicted diagonal intensities, I(0) values.

The parameter opt specifies if the spin type specific median and standard deviation of auo-relaxation (opt=2) values and back-predicted diagonal intensities, I(0) values (opt=3) are calculated are written to file.