Parameters

opt=integer
(default: 1)
plot =string
(default: izPlot)

Description

This command fits the diagonal decays to obtain the auto-relaxation (rho) values and back-predicted diagonal intensities, I(0) values.

The parameter opt specifies if the spin type specific median and standard deviation of auo-relaxation (opt=2) values and back-predicted diagonal intensities, I(0) values (opt=3) are calculated are written to file. With the back-predicted diagonal intensities there is a pdf file generated containing plots of the fitted intensities divided according to classes with the mean (green line) and std deviation (red line).