CYANA Command: enoe sig

From CYANA Wiki
Jump to navigation Jump to search

back to complete commands list

Parameters

opt=integer
(default: 1)

Description

This command fits the the cross peak buildups to obtain the experimental cross relaxation values values.

The parameter opt allows to fit the original experimental cross peak intensities (opt=1) or the spin-diffusion corrected ones (opt=2).

In the case of a single point measurement, sigma is obtained from sinh^-1 = log(sqrt(z^2+1) + z), where z corresponds to the experimental intensity.